{"id":861,"date":"2018-11-07T11:41:59","date_gmt":"2018-11-07T04:41:59","guid":{"rendered":"http:\/\/21314.lamdx.vinawebsite.vn\/?page_id=861"},"modified":"2020-03-24T15:29:34","modified_gmt":"2020-03-24T08:29:34","slug":"electromagnetic-fields-monitoring","status":"publish","type":"page","link":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/","title":{"rendered":"Electromagnetic Fields Monitoring"},"content":{"rendered":"<h3 class=\"nova-e-text nova-e-text--size-xxxl nova-e-text--family-sans-serif nova-e-text--spacing-l nova-e-text--color-grey-900 publication-details__title\" style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">Electromagnetic Fields Monitoring<\/span><\/h3>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">QCVN has announced the conditions for environmental testing in accordance with Decree 44\/2016 \/ ND-CP effective July 1, 2016.<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>1. Why need to measure electromagnetic fields<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">Evaluate activities that cause or suffer from industrial frequency electromagnetic fields in the working environment.<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>2. What are electromagnetic fields<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Electromagnetic: is a form of matter characterized by interaction between charged particles, generated by charged particles and a uniform field of electric and magnetic fields.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Industrial Frequency Electromagnetic Fields (Industrial Frequency Electromagnetic Fields): are electromagnetic waves with frequencies from 50Hz to 60Hz arising from electrostatic induction and electromagnetic fields from power sources, transmission lines and used devices electricity.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Electric field intensity: is the effective magnitude of the electric field vector (E) at a point, determined by the force (F) acting on a unit of charge (q) at a point in the field. , in volts per meter (V \/ m), ie.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Magnetic field intensity: is the effective magnitude of the magnetic field vector.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; The magnetic field strength is denoted by H, unit of amperes per meter (A \/ m).<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>TECHNICAL REGULATIONS<\/strong><\/span><\/p>\n<ol style=\"text-align: justify;\">\n<li><span style=\"color: #282828; font-size: 16px;\"><strong>Exposure allows the electric field<\/strong><\/span><\/li>\n<\/ol>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; When workers have no equipment to prevent the impact of electric fields, the working time at the place of electric field is specified in Table 1.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">Table 1. Permissible exposure to electric fields at work<\/span><\/p>\n<table style=\"height: 84px; width: 623px; border-style: solid; border-color: #f2f0f0;\" border=\"1\" width=\"0\" align=\"center\">\n<tbody>\n<tr style=\"height: 42px;\">\n<td style=\"padding-left: 30px; height: 42px; width: 135.92px;\"><span style=\"color: #282828; font-size: 16px;\">The electric field intensity E (kV \/ m)<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 75.9201px;\"><span style=\"color: #282828; font-size: 16px;\">&lt;5<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 89.2535px;\"><span style=\"color: #282828; font-size: 16px;\">5\u2264 E\u2264\u00a020<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 73.6979px;\"><span style=\"color: #282828; font-size: 16px;\">20&lt;E&lt;25<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 75.9201px;\"><span style=\"color: #282828; font-size: 16px;\">\u226525<\/span><\/td>\n<\/tr>\n<tr style=\"height: 42px;\">\n<td style=\"padding-left: 30px; height: 42px; width: 135.92px;\"><span style=\"color: #282828; font-size: 16px;\"><strong>Exposure time allows\u00a0<\/strong>(Minute)<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 75.9201px;\"><span style=\"color: #282828; font-size: 16px;\">Unlimited<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 89.2535px;\"><span style=\"color: #282828; font-size: 16px;\">(50\/E-2).60<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 73.6979px;\"><span style=\"color: #282828; font-size: 16px;\">10<\/span><\/td>\n<td style=\"padding-left: 30px; height: 42px; width: 75.9201px;\"><span style=\"color: #282828; font-size: 16px;\">Not exposed<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; When workers use protective equipment to prevent the impact of electric fields, the working time at the place of electric field shall be implemented according to separate regulations for each type of equipment.<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>2. Permissible exposure levels to magnetic fields<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">The allowable exposure level for magnetic fields is specified in Table 2.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">Table 2. The allowable exposure level from the school at work<\/span><\/p>\n<table style=\"width: 0px; border-color: #f2f0f0; border-style: solid;\" border=\"1\" width=\"0\" align=\"center\">\n<tbody>\n<tr>\n<td style=\"width: 333px; padding-left: 30px;\"><span style=\"color: #282828; font-size: 16px;\"><strong>Exposure time allows (hours)<\/strong><\/span><\/td>\n<td style=\"width: 301px; padding-left: 30px;\">\n<p class=\"LC20lb\"><span style=\"color: #282828; font-size: 16px;\"><strong>Magnetic field\u00a0&#8211;\u00a0H\u00a0<\/strong><strong>(A\/m)<\/strong><\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 333px; padding-left: 30px; text-align: center;\"><span style=\"color: #282828; font-size: 16px;\">8<\/span><\/td>\n<td style=\"width: 301px; padding-left: 30px; text-align: center;\"><span style=\"color: #282828; font-size: 16px;\">400<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 333px; padding-left: 30px; text-align: center;\"><span style=\"color: #282828; font-size: 16px;\">&lt;2<\/span><\/td>\n<td style=\"width: 301px; padding-left: 30px; text-align: center;\"><span style=\"color: #282828; font-size: 16px;\">4000<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: justify;\">\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>DETERMINING METHODS<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">Industrial frequency electromagnetic field measurement method is as follows:<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>1. Rule<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Measuring and evaluating electromagnetic fields in areas with sources of generation and areas of workers working under the influence of industrial frequency electromagnetic fields.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Measure at times: When new equipment is put into operation, when organizing a new workplace, when there is a change in equipment structure and periodic measurement.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; When measuring, it must strictly comply with the electric safety rules.<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>2. Instrumentation<\/strong><\/span><\/p>\n<div class=\"tlid-results-container results-container\" style=\"text-align: justify;\">\n<div class=\"tlid-result result-dict-wrapper\">\n<div class=\"result tlid-copy-target\">\n<div class=\"text-wrap tlid-copy-target\">\n<div class=\"result-shield-container tlid-copy-target\">\n<p><span class=\"tlid-translation translation\" style=\"color: #282828; font-size: 16px;\"><span title=\"\">&#8211; Measuring equipment must meet the provisions of the law on measurement and the industrial frequency magnetic field measuring device must have an antenna head to receive electromagnetic fields of frequency 50-60Hz.<\/span><\/span><\/p>\n<p><span style=\"font-size: 16px;\" title=\"\">&#8211; Limits of measurement:<\/span><\/p>\n<p><span style=\"font-size: 16px;\" title=\"\">+ Electric field: 0.1 V \/ m &#8211; minimum 30 kV \/ m<\/span><\/p>\n<p><span style=\"font-size: 16px;\" title=\"\">+ Magnetic field: 0.1 mA \/ m &#8211; minimum 5000 A \/ m<\/span><\/p>\n<p><span style=\"font-size: 16px;\"><span title=\"\">&#8211; Minimum sensitivity: Electric field 0.01 V \/ m;<\/span> <span title=\"\">Magnetic field: 0.01 mA \/ m.<\/span><\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>3. Measurement techniques<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Measuring electromagnetic fields at electrical equipment: Generators, transformers placed on the ground, working floor: Measure across the chest of the worker (if standing), horizontal head (if seated); If at other positions measured at the position of the body closest to the source.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Measuring electromagnetic fields at high-voltage equipment, transmission lines:<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">+ For power transmission lines measured under lines or distances 1; 2; 5m etc. &#8230; from the heart of the line or at the working position of the magnetic field from the line.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">+ For transformer stations: Measure at positions in the station according to technical titles.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">+ At each measuring position, it is necessary to measure 3 points at a height of 0.5m; 0.8m and 1.6m from the ground or working floor and 0.5m from the grounding component, taking the average result.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; Conduct measurement: Place the device on a rack or handheld. Turn on the device, measure the electric and magnetic fields at the points above. When the screen displays stable measurement results, read and write the results to the field measurement record.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>MANAGEMENT REGULATIONS<\/strong><\/span><\/p>\n<ol style=\"text-align: justify;\">\n<li><span style=\"color: #282828; font-size: 16px;\">Establishments having workers exposed to industrial electromagnetic fields must periodically measure and evaluate the electromagnetic field of the industrial frequency at least once a year and according to the provisions of the Labor Code and the Law of Security Labor safety and hygiene.<\/span><\/li>\n<li><span style=\"color: #282828; font-size: 16px;\">Employers must provide adequate means of labor protection for employees in accordance with the working environment in accordance with the Law on Safety and Occupational Hygiene.<\/span><\/li>\n<li><span style=\"color: #282828; font-size: 16px;\">If the industrial frequency electromagnetic field at the workplace exceeds the permitted limit, the employer must immediately implement measures to improve working conditions and protect workers&#8217; health<\/span><\/li>\n<\/ol>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\"><strong>IMPLEMENTATION<\/strong><\/span><\/p>\n<ol style=\"text-align: justify;\">\n<li><span style=\"color: #282828; font-size: 16px;\">This regulation applies in place of the Standard from the low frequency field and the standard of low frequency electric field strength in the Occupational Hygiene Standards issued under Decision No. 3733\/2002 \/ QD-BYT October 10 2002 of the Minister of Health.<\/span><\/li>\n<li><span style=\"color: #282828; font-size: 16px;\">The Department of Health Environmental Management &#8211; Ministry of Health presides and coordinates with relevant authorities to guide, implement and organize the implementation of this regulation.<\/span><\/li>\n<li><span style=\"color: #282828; font-size: 16px;\">Based on the practical requirements of management, the Department of Health Environmental Management is responsible for proposing the Ministry of Health to amend and supplement accordingly.<\/span><\/li>\n<li><span style=\"color: #282828; font-size: 16px;\">In case the national standards for industrial frequency electromagnetic fields cited in this Regulation are amended, supplemented or replaced, the provisions of the new documents shall apply.<\/span><\/li>\n<\/ol>\n<p style=\"text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">Refer to the standards for measuring labor environment:<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; National technical regulation QCVN 21: 2016 \/ BYT on high frequency electromagnetic fields &#8211; Exposure level allows high frequency electromagnetic fields at work<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; National Technical Regulation QCVN 23: 2016 \/ BYT on Ultraviolet Radiation &#8211; Exposure level allows ultraviolet radiation at work<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; National technical regulation QCVN 24: 2016 \/ BYT on Noise &#8211; Noise permissible exposure level at the workplace<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; National technical regulation QCVN 26: 2016 \/ BYT on Microclimate &#8211; Value for microclimate at workplace<\/span><\/p>\n<p style=\"padding-left: 30px; text-align: justify;\"><span style=\"color: #282828; font-size: 16px;\">&#8211; National technical regulation QCVN 27: 2016 \/ BYT on Forest &#8211; Allowable value at the workplace<\/span><\/p>\n<p style=\"text-align: justify;\">\n","protected":false},"excerpt":{"rendered":"<p>Electromagnetic Fields Monitoring QCVN has announced the conditions for environmental testing in accordance with Decree 44\/2016 \/ ND-CP effective July 1, 2016. 1. Why need to measure electromagnetic fields Evaluate activities that cause or suffer from industrial frequency electromagnetic fields in the working environment. 2. What are electromagnetic fields &#8211; Electromagnetic: is a form of&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1062,"parent":826,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-dichvu.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-861","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP<\/title>\n<meta name=\"description\" content=\"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP\" \/>\n<meta property=\"og:description\" content=\"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP\" \/>\n<meta property=\"og:url\" content=\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/\" \/>\n<meta property=\"og:site_name\" content=\"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs\" \/>\n<meta property=\"article:modified_time\" content=\"2020-03-24T08:29:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/\",\"url\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/\",\"name\":\"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP\",\"isPartOf\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg\",\"datePublished\":\"2018-11-07T04:41:59+00:00\",\"dateModified\":\"2020-03-24T08:29:34+00:00\",\"description\":\"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP\",\"breadcrumb\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#primaryimage\",\"url\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg\",\"contentUrl\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg\",\"width\":1024,\"height\":683,\"caption\":\"Quan trac dien tu truong\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/qcvn.com.vn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Service\",\"item\":\"https:\/\/qcvn.com.vn\/en\/service\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Labor environment monitoring\",\"item\":\"https:\/\/qcvn.com.vn\/en\/labor-environment-monitoring\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Electromagnetic Fields Monitoring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/#website\",\"url\":\"https:\/\/qcvn.com.vn\/en\/\",\"name\":\"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\",\"description\":\"Ph\u00e2n t\u00edch n\u01b0\u1edbc\",\"publisher\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/qcvn.com.vn\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/#organization\",\"name\":\"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\",\"url\":\"https:\/\/qcvn.com.vn\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg\",\"contentUrl\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg\",\"width\":1200,\"height\":476,\"caption\":\"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\"},\"image\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP","description":"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/","og_locale":"en_US","og_type":"article","og_title":"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP","og_description":"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP","og_url":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/","og_site_name":"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM","article_publisher":"https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs","article_modified_time":"2020-03-24T08:29:34+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/","url":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/","name":"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP","isPartOf":{"@id":"https:\/\/qcvn.com.vn\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#primaryimage"},"image":{"@id":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#primaryimage"},"thumbnailUrl":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg","datePublished":"2018-11-07T04:41:59+00:00","dateModified":"2020-03-24T08:29:34+00:00","description":"Electromagnetic Fields Monitoring Decree 44\/2016 \/ ND-CP","breadcrumb":{"@id":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#primaryimage","url":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg","contentUrl":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2018\/11\/trung-tam-quan-trac-moi-truong-qcvn-15-1024x683.jpg","width":1024,"height":683,"caption":"Quan trac dien tu truong"},{"@type":"BreadcrumbList","@id":"https:\/\/qcvn.com.vn\/en\/electromagnetic-fields-monitoring\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/qcvn.com.vn\/en\/"},{"@type":"ListItem","position":2,"name":"Service","item":"https:\/\/qcvn.com.vn\/en\/service\/"},{"@type":"ListItem","position":3,"name":"Labor environment monitoring","item":"https:\/\/qcvn.com.vn\/en\/labor-environment-monitoring\/"},{"@type":"ListItem","position":4,"name":"Electromagnetic Fields Monitoring"}]},{"@type":"WebSite","@id":"https:\/\/qcvn.com.vn\/en\/#website","url":"https:\/\/qcvn.com.vn\/en\/","name":"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM","description":"Ph\u00e2n t\u00edch n\u01b0\u1edbc","publisher":{"@id":"https:\/\/qcvn.com.vn\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/qcvn.com.vn\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/qcvn.com.vn\/en\/#organization","name":"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM","url":"https:\/\/qcvn.com.vn\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/","url":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg","contentUrl":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg","width":1200,"height":476,"caption":"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM"},"image":{"@id":"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs"]}]}},"_links":{"self":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages\/861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/comments?post=861"}],"version-history":[{"count":0,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages\/861\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages\/826"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/media\/1062"}],"wp:attachment":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/media?parent=861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}