{"id":831,"date":"2018-11-08T16:08:18","date_gmt":"2018-11-08T09:08:18","guid":{"rendered":"http:\/\/21314.lamdx.vinawebsite.vn\/?page_id=831"},"modified":"2019-03-05T11:35:17","modified_gmt":"2019-03-05T04:35:17","slug":"monitoring-indicators-microclimate","status":"publish","type":"page","link":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/","title":{"rendered":"Monitoring indicators microclimate"},"content":{"rendered":"<h3 style=\"text-align: justify;\"><span style=\"color: #282828;\">Monitoring indicators microclimate<\/span><\/h3>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">Environmental monitoring department QCVN Technical Joint Stock Company includes the following tasks:<\/span><\/p>\n<ul style=\"text-align: justify;\">\n<li><span style=\"color: #282828;\">Monitoring and measuring environmental indicators in the field<\/span><\/li>\n<li><span style=\"color: #282828;\">Sampling to analytical in laboratory.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">Monitoring the working environment including monitoring micro-climate indicators in the working environment according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate &#8211; Values for microclimate at workplaces Value work allows microclimate at work<\/span><\/p>\n<table style=\"height: 73px; border-collapse: collapse; border-style: solid; border-color: #f2f0f0;\" border=\"2\">\n<tbody>\n<tr style=\"height: 10px;\">\n<td style=\"width: 91px; height: 10px; text-align: center;\"><span style=\"color: #282828;\"><strong>Level<\/strong><\/span><\/td>\n<td style=\"width: 158px; height: 10px; text-align: center;\"><span style=\"color: #282828;\"><strong>Temperature\u00a0(<sup>o<\/sup>C)<\/strong><\/span><\/td>\n<td style=\"width: 136px; height: 10px; text-align: center;\"><span style=\"color: #282828;\"><strong>Air humidity<\/strong><strong>\u00a0(%)<\/strong><\/span><\/td>\n<td style=\"width: 185px; height: 10px; text-align: center;\"><span style=\"color: #282828;\"><strong>Speed air movement<\/strong><strong style=\"font-family: inherit; font-size: inherit;\">(m\/s)<\/strong><\/span><\/td>\n<td style=\"width: 237px; height: 10px; text-align: center;\"><span style=\"color: #282828;\"><strong>Thermal radiation intensity exposure area\u00a0<\/strong><strong style=\"font-family: inherit; font-size: inherit;\">(W\/m<sup>2<\/sup>)<\/strong><\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 91px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">Low<\/span><\/td>\n<td style=\"width: 158px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">20 \u0111\u1ebfn 40<\/span><\/td>\n<td style=\"width: 136px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">40 \u0111\u1ebfn 80<\/span><\/td>\n<td style=\"width: 185px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">0,1 \u0111\u1ebfn 1,5<\/span><\/td>\n<td style=\"width: 237px; height: 63px;\" rowspan=\"3\">\n<p style=\"text-align: center;\"><span style=\"color: #282828;\">35 exposure of 50% of the human body<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #282828;\">70 exposure of 25% to 50% of the human body<\/span><\/p>\n<p style=\"text-align: center;\"><span style=\"color: #282828;\">100 exposure below 25% of the area on the human body<\/span><\/p>\n<\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 91px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">Medium<\/span><\/td>\n<td style=\"width: 158px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">18 \u0111\u1ebfn 32<\/span><\/td>\n<td style=\"width: 136px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">40 \u0111\u1ebfn 80<\/span><\/td>\n<td style=\"width: 185px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">0,2 \u0111\u1ebfn 1,5<\/span><\/td>\n<\/tr>\n<tr style=\"height: 21px;\">\n<td style=\"width: 91px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">N\u1eb7ng<\/span><\/td>\n<td style=\"width: 158px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">16 \u0111\u1ebfn 30<\/span><\/td>\n<td style=\"width: 136px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">40 ddessn 80<\/span><\/td>\n<td style=\"width: 185px; height: 21px; text-align: center;\"><span style=\"color: #282828;\">0,3 \u0111\u1ebfn 1,5<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul style=\"list-style-type: disc; text-align: justify;\">\n<li style=\"text-align: justify;\"><span style=\"color: #282828;\">For hot working conditions, high humidity, the air movement speed in the workplace can increase to 2 m \/ s.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"color: #282828;\">For working conditions in air-conditioned rooms, the air movement speed may be below 0.1 m \/ s for light labor, below 0.2 m \/ s for average labor and less than 0.3 m \/ s for heavy labor if ventilation in the room ensures that the CO2 concentration meets the permitted standard.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"color: #282828;\">The temperature difference according to the height of the working position does not exceed 3 \u00b0 C.<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"color: #282828;\">The difference in the horizontal temperature of the working area shall not exceed 4 \u00b0 C for light labor, not exceeding 5 \u00b0 C for average labor and no more than 6 \u00b0 C for heavy labor. The temperature difference in production and outdoor areas does not exceed 5 \u00b0 C.<\/span><\/li>\n<\/ul>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\"><strong>I. DETERMINING METHODS<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">Method of determination of microclimate according to TCVN 5508 &#8211; 2009: Working atmosphere &#8211; Requirements on microclimate conditions and measurement methods.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\"><strong>II. MANAGEMENT REGULATIONS<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">1. Establishments having laborers exposed to microclimate elements must periodically organize the inspection and examination of micro-workplace climate at least once a year and according to the provisions of the Labor Code and the Law. labor safety and hygiene.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">2. Employers must provide adequate means of labor protection to employees in accordance with the working environment in accordance with the law on safety and occupational health.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">3. If the microclimate at the workplace does not meet the permitted value, the employer must immediately implement measures to improve working conditions and protect the health of workers.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\"><strong>III. ORGANIZATION OF IMPLEMENTATION<\/strong><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">1. This Regulation applies to replace microclimate standards in the Occupational Hygiene Standards according to Decision No. 3733\/2002 \/ QD-BYT dated 10\/10\/2002 of the Minister of Health.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">2. Department of Health Environmental Management &#8211; Ministry of Health presides and coordinates with relevant authorities to guide, implement and organize the implementation of this regulation.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">3. Based on the practical requirements of management, the Medical Environment Management Department shall have to propose the Ministry of Health to amend and supplement them accordingly.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #282828;\">4. In the case of national standards, international standards of microclimate cited in this regulation amended, supplemented or replaced, the provisions of new documents shall apply.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Monitoring indicators microclimate Environmental monitoring department QCVN Technical Joint Stock Company includes the following tasks: Monitoring and measuring environmental indicators in the field Sampling to analytical in laboratory. Monitoring the working environment including monitoring micro-climate indicators in the working environment according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate &#8211; Values&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":826,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-dichvu.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-831","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Monitoring indicators microclimate QCVN 26: 2016 \/ BYT<\/title>\n<meta name=\"description\" content=\"Monitoring indicators microclimate according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate, QCVN centre\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Monitoring indicators microclimate QCVN 26: 2016 \/ BYT\" \/>\n<meta property=\"og:description\" content=\"Monitoring indicators microclimate according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate, QCVN centre\" \/>\n<meta property=\"og:url\" content=\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/\" \/>\n<meta property=\"og:site_name\" content=\"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs\" \/>\n<meta property=\"article:modified_time\" content=\"2019-03-05T04:35:17+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/\",\"url\":\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/\",\"name\":\"Monitoring indicators microclimate QCVN 26: 2016 \/ BYT\",\"isPartOf\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/#website\"},\"datePublished\":\"2018-11-08T09:08:18+00:00\",\"dateModified\":\"2019-03-05T04:35:17+00:00\",\"description\":\"Monitoring indicators microclimate according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate, QCVN centre\",\"breadcrumb\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/qcvn.com.vn\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Service\",\"item\":\"https:\/\/qcvn.com.vn\/en\/service\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Labor environment monitoring\",\"item\":\"https:\/\/qcvn.com.vn\/en\/labor-environment-monitoring\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Monitoring indicators microclimate\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/#website\",\"url\":\"https:\/\/qcvn.com.vn\/en\/\",\"name\":\"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\",\"description\":\"Ph\u00e2n t\u00edch n\u01b0\u1edbc\",\"publisher\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/qcvn.com.vn\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/#organization\",\"name\":\"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\",\"url\":\"https:\/\/qcvn.com.vn\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg\",\"contentUrl\":\"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg\",\"width\":1200,\"height\":476,\"caption\":\"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM\"},\"image\":{\"@id\":\"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Monitoring indicators microclimate QCVN 26: 2016 \/ BYT","description":"Monitoring indicators microclimate according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate, QCVN centre","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/","og_locale":"en_US","og_type":"article","og_title":"Monitoring indicators microclimate QCVN 26: 2016 \/ BYT","og_description":"Monitoring indicators microclimate according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate, QCVN centre","og_url":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/","og_site_name":"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM","article_publisher":"https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs","article_modified_time":"2019-03-05T04:35:17+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/","url":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/","name":"Monitoring indicators microclimate QCVN 26: 2016 \/ BYT","isPartOf":{"@id":"https:\/\/qcvn.com.vn\/en\/#website"},"datePublished":"2018-11-08T09:08:18+00:00","dateModified":"2019-03-05T04:35:17+00:00","description":"Monitoring indicators microclimate according to the National Technical Regulation QCVN 26: 2016 \/ BYT on Microclimate, QCVN centre","breadcrumb":{"@id":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/qcvn.com.vn\/en\/monitoring-indicators-microclimate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/qcvn.com.vn\/en\/"},{"@type":"ListItem","position":2,"name":"Service","item":"https:\/\/qcvn.com.vn\/en\/service\/"},{"@type":"ListItem","position":3,"name":"Labor environment monitoring","item":"https:\/\/qcvn.com.vn\/en\/labor-environment-monitoring\/"},{"@type":"ListItem","position":4,"name":"Monitoring indicators microclimate"}]},{"@type":"WebSite","@id":"https:\/\/qcvn.com.vn\/en\/#website","url":"https:\/\/qcvn.com.vn\/en\/","name":"C\u00d4NG TY CP K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM","description":"Ph\u00e2n t\u00edch n\u01b0\u1edbc","publisher":{"@id":"https:\/\/qcvn.com.vn\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/qcvn.com.vn\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/qcvn.com.vn\/en\/#organization","name":"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM","url":"https:\/\/qcvn.com.vn\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/","url":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg","contentUrl":"https:\/\/qcvn.com.vn\/wp-content\/uploads\/2019\/01\/logo-QCVN.jpg","width":1200,"height":476,"caption":"C\u00d4NG TY C\u1ed4 PH\u1ea6N K\u1ef8 THU\u1eacT TI\u00caU CHU\u1ea8N QCVN VI\u1ec6T NAM"},"image":{"@id":"https:\/\/qcvn.com.vn\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/kythuatieuchuanQCVN\/?ref=br_rs"]}]}},"_links":{"self":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages\/831","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/comments?post=831"}],"version-history":[{"count":0,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages\/831\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/pages\/826"}],"wp:attachment":[{"href":"https:\/\/qcvn.com.vn\/en\/wp-json\/wp\/v2\/media?parent=831"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}